Study on infrared colorimetric temperature measurement in vacuum furnace

XiantaoYang , Jie Yang, Yue Gu

Abstract


In view of the situation that on-line continuous temperature measurement can not be realized and the cost of thermocouple
temperature measurement is high, the infrared dual-light colorimetric temperature measurement method is proposed in this paper. Based on Wien’s
formula, a temperature model is established. Through theoretical analysis and experiment to select the appropriate double light wavelength, through
laboratory calibration and fi eld calibration proved the feasibility of the infrared double light colorimetric temperature measurement system adopted
in this paper, not only can realize online continuous temperature measurement, can realize smelting in strict accordance with the smelting process
curve, to ensure the time of steel and the content of each element, it is of great signifi cance to China’s metallurgical industry

Keywords


vacuum furnace, double light colorimetry, temperature measurement, smelting

Full Text:

PDF

References


[1] ZifengHu,Zhaojun Wang,Lu Jin, etal. The modulation double color infrared measuring temperature real-time error compensation method research [J].

Optics, 2020, 42 (3) : 7. DOI: 10.3969 / j.i SSN. 1005-5630.2020.03.003.

[2] YuanfengDai,Xiaojun Zhu,Tinglin Gu. Design of Two-color colorimetric temperature measurement System based on CCD [J]. Electronic Technology and

Software Engineering, 2020, 000(008):P.104-105.




DOI: https://doi.org/10.18686/mcs.v5i5.2068