Treatment of sloughter water using reaction-regulation integrated

Shumei Zheng

Abstract


In view of the extension and renovation requirement of a waste water treatment plant, a system with reaction-preparation integrated review loop bioreactor (rpir) as the core technology was used to treat waste water. the operation results showold that, the average removal rates of CODCr, NH3.-N, TN and TP were 94.1%, 90.1%, 68.4% and 85.9% specially, the average mass concentrations of them were 110.8, 16.0, 3.8 and 81.5 mg/L specially with the annual reduction of 970.9, 80.6, 94.9 and 13.7 t specially. the average mass concentration of SS in effluent water was 17 mg/L. it could be seen that, the CODCr, NH3.-N and SS concentrations of effluent water were all superior to the requirements of Grade 2 in GB 13457-1992 discharge standard of water polls for meat packaging industry. The SV30Of the rpir aerobic reaction zone was 35%-45%, the mass concentrations of MLSS and MLVSS could remain at about 6 000 and 3 650 mg/L specially. the floor space of rpir biochemical reaction zone of the said new system for one ton water treatment was 0.16 m2..


Keywords


reaction-regulation integrated reactor Loop Reactor

Full Text:

PDF

References


Kim ke-yong,Jin Shui Yu,Zhou Yong,Wait..Propylene Oxide saponification wastewater treatment and reuse LawJ .Water Treatment Technology,2010,36(5.):78-82.

Lan HuiXia,Wang Lele.Cultivation and degradation effect of propylene oxide Degrading Strain in Wastewater ResearchJ .Sichuan Environment,2009,28(4.):28-30.

Liao jiaxia.Study on the Construction of genetically engineered bacteria for degradation of organic chlorideD .Wuhan:Wu Hantech University,2009.

Wu Chong.High Salt propylene oxide Wastewater-Biochemical Treatment ResearchD .Harbin:Ha Erbin University of Technology,2007.

Li Meng,Zhang Qian.Experimental Study on the Treatment of propylene oxide Wastewater by pre-oxidation process J .Journal of Wuhan University of Technology,2008,30(3.):43-45.

Jiang Tao,Liu Yong.Study on Biochemical Treatment efficiency of propylene oxide Wastewater with different salt contents J .China chlor alkali,2014,(1.):39-40.

Meng qingfan.Study on Biochemical Treatment of high salinity propylene oxide WastewaterJ .Industrial water and Wastewater,2000,31(1.):19-21..

Qian Hui.Biological Treatment of propylene oxide WASTEWATER AND HIGH SALINITY WASTEWATERJ .Energy and environment,2010,(1.):66-67.

Zhu Shuai,Chai Tao.Aeration+Chemical Flocculation pretreatment Epoxy Propane WastewaterJ .Ring Environment Engineering Journal20148(2):605-610.

Zhang LiKing Vineland.Deep Well Aeration Biochemical Method Processing Epoxy Propane saponification wastewaterJ .Industrial Water Treatment200121(2):35-37.

Wangcz jia.Epoxy Propane saponification wastewater activity sludge in microbial of resistance salinity domestication and Community AnalysisD .Jinan:Jinan University2013.

Hui TianxiangWang Xiaojun.High Salt Epoxy Propane Production Wastewater Treatment Engineering ReformJ ., China Water Supply Drainage201733(6):95-97.

King pioneer.Epoxy Propane,Epichlorohydrin chemical comprehensive wastewater treatment engineering instanceJ .Industrial Water and Wastewater201546(3):46-49.

Takeshi once.High Salt Epoxy Propane wastewater biochemical Processing Device Engineering Design and Operation ResearchD ., Beijing:, China University of Petroleum2006.


Refbacks

  • There are currently no refbacks.